PM/F

PM/F

Pressure/Vacuum Relief Valve

Pilot-operated diaphragm valve

Функция и описание

The PM/F type pilot-controlled PROTEGO® diaphragm valve is a highly developed valve for pressure and vacuum relief. It is primarily used as a safety device for outbreathing in tanks, containers, and process engineering equipment and it also offers reliable protection from vacuum and overpessure. It prevents the intake of air and unacceptable product vapor loss up to the set point. The valve can also be used as inbreathing valve. The main valve is directly controlled when it is exposed to a vacuum; e.g., it functions as a weight-loaded diaphragm valve.

The main valve is controlled by a pilot valve. The pilot valve is controlled by the tank pressure. The tank medium does not continuously flow through the pilot. The set pressure is adjusted by stretching or relaxation of a spring.

As the operating pressure increases, the closing force acting on the main valve also rises; e.g. the valve tightness increases to prevent leakage until the set pressure is reached. After the valve responded within 10% pressure rise, it immediately opens completely, and the nominal volumetric flow is discharged through a fully open valve. If this level is exceeded, the pressure increase follows the performance curve. Up to the set pressure, the tank pressure is maintained with a tightness that is far superior to the conventional standard due to the superior manufacturing technology. This feature is achieved by valve seats made of high-grade stainless steel with precisely ground valve pallets. After the excess pressure is discharged, the valve reseats and again provides a tight seal.

Особые признаки и преимущества

  • controlled by corrosion-resistant control valve
  • the tank medium does not continuously flow through the pilot valve
  • 10% technology for minimum pressure rise up to full lift
  • extreme tightness and hence least possible product losses and reduced environmental pollution
  • set pressure is close to full lift pressure, which results in high level of design freedom and product savings
  • the control diaphragm of the main valve is shielded from low temperatures - high-level durability
  • high flow capacity
  • can be used in areas subject to an explosion hazard
  • self draining

Таблица параметров

To select the nominal size (DN), use the flow capacity charts on the following pages

DN180 / 3" 100 / 4" 150 / 6" 200 / 8" 250 / 10" 300 / 12"
DN2100 / 4"150 / 6"200 / 8"250 / 10"300 / 12"350 / 14"
a225 / 8.86250 / 9.87325 / 12.80375 / 14.76450 / 17.72500 / 19.69
b150 / 5.91175 / 6.89225 / 8.86250 / 9.84270 / 10.63300 / 12.81
c275 / 10.83330 / 12.99445 / 17.52550 / 21.65665 / 26.18785 / 30.91
d370 / 14.57425 / 16.73515 / 20.28590 / 23.23675 / 26.57750 / 29.53
e700 / 27.56770 / 30.31860 / 33.86915 / 36.02970 / 38.191060 / 41.73
f35 / 1.3840 / 1.5740 / 1.5750 / 1.9750 / 1.9750 / 1.97
DN180 / 3" 100 / 4" 150 / 6" 200 / 8" 250 / 10" 300 / 12"
DN2100 / 4"150 / 6"200 / 8"250 / 10"300 / 12"350 / 14"
a225 / 8.86250 / 9.87325 / 12.80375 / 14.76450 / 17.72500 / 19.69
b150 / 5.91175 / 6.89225 / 8.86250 / 9.84270 / 10.63300 / 12.81
c275 / 10.83330 / 12.99445 / 17.52550 / 21.65665 / 26.18785 / 30.91
d370 / 14.57425 / 16.73515 / 20.28590 / 23.23675 / 26.57750 / 29.53
e700 / 27.56770 / 30.31860 / 33.86915 / 36.02970 / 38.191060 / 41.73
f35 / 1.3840 / 1.5740 / 1.5750 / 1.9750 / 1.9750 / 1.97

размер в мм

PM/F

Выбор материала корпуса

DesignA B
HousingAluminiumStainless Steel
Valve seatStainless SteelStainless Steel
SealingKL-C-4106KL-C-4106
Main diaphragm protectionStainless SteelStainless Steel
Pilot linesStainless SteelStainless Steel
Pilot housingAluminiumStainless Steel
Pilot diaphragmFEPFEP
DesignA B
HousingAluminiumStainless Steel
Valve seatStainless SteelStainless Steel
SealingKL-C-4106KL-C-4106
Main diaphragm protectionStainless SteelStainless Steel
Pilot linesStainless SteelStainless Steel
Pilot housingAluminiumStainless Steel
Pilot diaphragmFEPFEP

Special materials upon request

Material selection for valve pallet

Design ABC
Pressure range [mbar]

[inch W.C.]
-3,0 up to -4*

-1.2 up to -1.6*
-4 up to -5*

-1.6 upm to -2.0*
-5 up to -10*

-2.0 up to -4.0*
Valve palletAluminiumStainless SteelStainless Steel
DiaphragmFEPFEPFEP
Diaphragm palletAluminiumAluminiumStainless Steel
Design ABC
Pressure range [mbar]

[inch W.C.]
-3,0 up to -4*

-1.2 up to -1.6*
-4 up to -5*

-1.6 upm to -2.0*
-5 up to -10*

-2.0 up to -4.0*
Valve palletAluminiumStainless SteelStainless Steel
DiaphragmFEPFEPFEP
Diaphragm palletAluminiumAluminiumStainless Steel

* The indicated vacuum ranges depend on the nominal size and can differ.

The pressure Setting can be combined with any vacuum setting. Special materials upon request

PM/F

Вид фланцевого соединения

EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF
EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF

other types upon request

Модели и спецификация

The pilot controlled diaphragm valve is equipped with one control valve (pilot valve). For ensuring optimum operation safety in case of any failures or damages, it is recommended to install an emergency pilot valve.

Basic design of pressure/vacuum relief valve with a control pilot valve

PM/F

Basic design of pressure/vacuum relief valve with a control pilot valve

PM/F

Additional special devices available upon request.

Settings

Pressure:

+10 mbar

+350 mbar

+4 inch W.C.

+140 inch W.C.

Vacuum:

-3.0 mbar

-10 mbar

-1.2 inch W.C.

Higher or lower settings upon request.

PM/F

Диаграммы пропускной способности

Диаграммы пропускной способности были определены с помощью калибрированной и сертифицированной объединением технического надзора (TÜV) проточной измерительной установки. Пропускная способность V. в м³/час определена воздухом при нормальных атмосферных условиях в соответствии с ISO 6358 (20°C, 1 бар). Преобразование для различных плотностей и температур см. главу 1: Технические основы

PM/F
PM/F