ER-V-LP

ER-V-LP

Emergency pressure relief valve

Función y Descripción

The PROTEGO® Type ER-V-LP valve is a sophisticated pressure relief valve for applications in which a high flow effi ciency is of the essence. It is primarily used as an emergency pressure relief valve on storage tanks, vessels, silos, and process engineering equipment; it offers reliable protection against excessive overpressure and prevents excessive product loss at pressures as high as close to the set-to-operate pressure. It is designed to relieve particularly large quantities to prevent the vessel rupturing in an emergency case.

The valve will start to open as soon as the set-to-operate pressure is reached and only requires a 10% pressure increase or opening pressure differential until full lift. Dedicated R & D investments have enabled PROTEGO® to develop a new valve pallet technology for which a patent has been granted. This patented valve pallet technology allows the area characteristic typical of safety valves to be also applied to lower-pressure applications, while ensuring that minimum leakagerate requirements are met.

Adopting this new patented valve pallet technology permits the valve to be set to just 10% below the maximum allowable working pressure of the tank and still vent the required mass flow.

Due to the sophisticated manufacturing technology, the tank pressure is maintained up to the set-to-operate pressure, with seal-tight requirements far above common standards being met. Once the excess pressure is relieved, the valve reseats and seals tight again.

Características especiales y ventajas

  • patented valve pallet technology guarantees that minimum leakage-rate requirements can be met and, hence, least possible product losses and reduced impact on the environment are ensured
  • 10% Technology for minimum pressure increase until full lift
  • set-to-operate pressure close to the opening pressure; hence, best possible pressure management of the system
  • high flow efficiency
  • valve pallet is guided within a closed system and, thus, protected from atmospheric influence
  • suited for use in hazardous areas
  • rugged body design
  • movable components are secured
  • best technology for API tanks

Dimensiones

To select the nominal size (DN), use the flow capacity chart on the following page

DN200 / 8" 250 / 10" 300 / 12"350 / 14" 400 / 16"450 / 18"500 / 20" 600 / 24" 700 / 28"
a343 / 13.50406 / 15.98483 / 19.02533 / 20.98597 / 23.50635 / 25.00699 / 27.52813 / 32.01837 / 32.95
b378 / 14.88399 / 15.71409 / 16.10440 / 17.32455 / 17.91464 / 18.27481 / 18.94556 / 21.89571 / 22.48
DN200 / 8" 250 / 10" 300 / 12"350 / 14" 400 / 16"450 / 18"500 / 20" 600 / 24" 700 / 28"
a343 / 13.50406 / 15.98483 / 19.02533 / 20.98597 / 23.50635 / 25.00699 / 27.52813 / 32.01837 / 32.95
b378 / 14.88399 / 15.71409 / 16.10440 / 17.32455 / 17.91464 / 18.27481 / 18.94556 / 21.89571 / 22.48

Dimensiones en mm / pulgadas

ER-V-LP

Selección de materiales

Design AB
HousingSteelStainless Steel
Valve seatStainless SteelStainless Steel
Valve palletStainless SteelStainless Steel
SealingStainless SteelStainless Steel
Design AB
HousingSteelStainless Steel
Valve seatStainless SteelStainless Steel
Valve palletStainless SteelStainless Steel
SealingStainless SteelStainless Steel

Special materials upon request

ER-V-LP

Tipo de bridas de conexión

EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF
EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF

other types upon request

Modelo y especificación

The valve pallet is weight-loaded. Higher set-to-operate pressures are achieved with Types ER/V and ER/VH (lever-operated) valves or Type ER/V-F (spring-loaded) valves.

Pressure valve in basic design

ER-V-LP

Pressure valve in basic design

ER-V-LP

Additional special devices available upon request.

Settings

+3.4 mbar

+15 mbar

+1.4 inch W.C.

+6 inch W.C.

For higher pressure settings, see types ER/V, ER/VH and ER/V-F.

ER-V-LP

Diagrama de flujo volumétrico

Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.

ER-V-LP
ER-V-LP