EH/0S

EH/0S

Vent Cap, End-of-Line

Función y Descripción

The PROTEGO® EH/0S vent cap allows vessels which are not pressurized to vent. This device prevents rain and dirt entering the vent line. The PROTEGO® EH/0S vent cap is not flame transmission proof. It is often used in combination with Detonation flame arresters, when those are used in ventlines, installed at a position which creates a long run up distance from the end of the vent line to prevent endurance burning. The PROTEGO® EH/0S will then be installed at the end of that vent line to prevent particles or rain from entering the line. The vent cap PROTEGO® EH/0S main components are a housing (1), a weather hood (2) and a protection screen (3). The device is equipped with a fixed weather hood out of metal. The protection screen prevents particles or rain from entering the line.

Características especiales y ventajas

  • vent cap provides protection against environmental impact (harsh weather conditions, bird nests, etc.)
  • cost effective device
  • almost maintenance free
  • certified flow performance curves

Dimensiones

To select the nominal size (DN), please use the flow capacity charts on the following pages

DN100 / 4" 150 / 6"200 / 8"250 / 10"300 / 12"350 / 14"400 / 16"500 / 20"600 / 24"
a295 / 11.61550 / 21.65550 / 21.65600 / 23.62600 / 23.62600 / 23.62650 / 25.59800 / 31.501000 / 39.37
b230 / 9.06240 / 9.45240 / 9.45325 / 12.80320 / 12.60335 / 13.19370 / 14.57385 / 15.16520 / 20.47
DN100 / 4" 150 / 6"200 / 8"250 / 10"300 / 12"350 / 14"400 / 16"500 / 20"600 / 24"
a295 / 11.61550 / 21.65550 / 21.65600 / 23.62600 / 23.62600 / 23.62650 / 25.59800 / 31.501000 / 39.37
b230 / 9.06240 / 9.45240 / 9.45325 / 12.80320 / 12.60335 / 13.19370 / 14.57385 / 15.16520 / 20.47

Dimensiones en mm / pulgadas

EH/0S

Selección de materiales

Design AB
HousingSteelStainless Steel
Weather hoodStainless SteelStainless Steel
Design AB
HousingSteelStainless Steel
Weather hoodStainless SteelStainless Steel

Special materials upon request

EH/0S

Tipo de bridas de conexión

EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF
EN 1092-1; Form B1
ASME B16.5; 150 lbs RFSF

other types upon request

Modelo y especificación

Following designs are available:

Vent cap, basic design

EH/0S

Vent cap, basic design

EH/0S

Special designs available on request

EH/0S

Diagrama de flujo volumétrico

Los diagramas de flujo volumétrico han sido determinados con un banco de pruebas de caudal calibrado y certifi - cado por TÜV. El flujo volumétrico V. en [m³/h] y el CFH se refi eren a las condiciones estándar de referencia de aire según ISO 6358 (20°C, 1bar). La conversión a otras densidades y temperaturas están referidas en el Vol. 1: “Fundamentos Técnicos”.

EH/0S
EH/0S