Deflagration Flame Arrester, End-of-Line

Function and Description

The PROTEGO® BE/AD end-of-line deflagration flame arrester provides protection against atmospheric deflagrations. The device is typically installed on vent lines of small vessels and plant equipment which is not pressurized. For safe application it is important that an endurance burning situation can be excluded, so typically it is installed on vents lines which discharge vapor for a short time period only. The device prevents flame transmission from atmospheric deflagration into the vessel or plant.

The PROTEGO® BE/AD consists of a housing (1), a weather hood (2) and the PROTEGO® flame arrester unit (3). The device is equipped with a metal weather hood. The FLAMEFILTER® gap size will depend on the devices intended use. Detailing the operating conditions such as the temperature, pressure, explosion group and the composition of the fluid, enables PROTEGO® to select the best end-of-line deflagration flame arrester for your application. The PROTEGO® BE/AD series end-of-line deflagration flame arrester is available for substances from explosion groups IIA to IIC (NEC groups D to B).

The standard design can be used with operating temperature of up to +60°C / 140°F.

Type-approved in accordance with the current ATEX Directive and EN ISO 16852 as well as other international standards.

Features and Advantages

  • Weather hood provides protection against environmental impact (harsh weather conditions, bird nests, etc.)
  • easy maintenance
  • quick removal of FLAMEFILTER®
  • available with threaded connection
  • provides protection against atmospheric deflagration
  • low operating and lifecycle cost
  • cost effective device
  • cost effective spare parts

Dimensions

DN15 / G ½"20 / G ¾"25 / G 1"32 / G 1¼"40 / G 1½"50 / G 2"
a116 / 4.57116 / 4.57116 / 4.57116 / 4.57200 / 7.87200 / 7.87
b80 / 3.1580 / 3.1585 / 3.3585 / 3.35150 / 5.91150 / 5.91
DN15 / G ½"20 / G ¾"25 / G 1"32 / G 1¼"40 / G 1½"50 / G 2"
a116 / 4.57116 / 4.57116 / 4.57116 / 4.57200 / 7.87200 / 7.87
b80 / 3.1580 / 3.1585 / 3.3585 / 3.35150 / 5.91150 / 5.91

Dimensions in mm / inches

BE/AD

Material selection

DesignABC
HousingSteelStainless SteelHastelloy
Weather HoodStainless SteelStainless SteelStainless Steel
FLAMEFILTER®Stainless SteelStainless SteelHastelloy
DesignABC
HousingSteelStainless SteelHastelloy
Weather HoodStainless SteelStainless SteelStainless Steel
FLAMEFILTER®Stainless SteelStainless SteelHastelloy

Special materials upon request

BE/AD

Selection of explosion group

MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
≥ 0,65 mmIIB3C
< 0,5 mmIICB
MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
≥ 0,65 mmIIB3C
< 0,5 mmIICB

Special approvals upon request

Specification of max. operating temperature

≤ 60°C / 140°FTmaximum allowable operating temperature in °C
-Designation
≤ 60°C / 140°FTmaximum allowable operating temperature in °C
-Designation

higher operating temperatures upon request

Type of connection

Pipe thread DIN ISO 228-1DIN
Pipe thread DIN ISO 228-1DIN

other types of thread upon request

Design Types and Specifications

Following designs are available:

Deflagration flame arrester, end-of-line, basic design

BE/AD

Deflagration flame arrester, end-of-line, basic design

BE/AD

Special designs available on request

BE/AD

Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). Conversion to other densities and temperatures refer to Vol. 1: “Technical Fundamentals”.

BE/AD